# 8 · MaintNode devices and automatic data

Routes cover the readings a person takes. **MaintNode** covers the rest — the
hardware that measures your equipment continuously and sends the readings into
Mechbase on its own, with nobody in the loop. This chapter explains what MaintNode
is, how you claim a device and connect its inputs to measurement points, and how to
tell it's healthy.

## What MaintNode is

A **MaintNode** is a small edge computer installed at your site, wired to the
sensors on your equipment. It measures on a schedule, keeps every reading on its own
storage, and uploads them to Mechbase over a secure internet connection — so a
network outage never loses data; the readings simply catch up when the link
returns. Those readings land on the matching **measurement points**, where they
trend, get checked against alarm limits, and drive asset health exactly like any
other reading.

A MaintNode reads three kinds of input:

- **Built-in inputs** — sixteen analog channels (two stacked boards of eight) for
  accelerometers, 0–10 V and 4–20 mA transmitters, and tachometers.
- **USB DAQ** — an external USB-201 acquisition module.
- **Modbus** — registers and coils read from a PLC, drive, or gateway over **TCP**
  or **serial (RTU)**.

Three ideas make the rest of this chapter make sense:

- **A device has channels.** Each input is a **channel**, numbered from 0.
- **Channels are grouped.** An **acquisition group** is a set of channels on one
  device that are measured together, on the same hardware and the same schedule —
  for example *"Compressor vibration: built-in inputs, every 20 minutes, 4096 samples
  at 4096 Hz"*.
- **A point is fed by a channel.** You connect the two on the point's **Sources**
  ([Working with assets](assets.md#how-a-point-gets-its-data-sources)) —
  *this point is fed by channel 0 of that group on that device*.

> **Screenshot needed (hardware):** a photo of a MaintNode device installed on or
> near equipment, with its label visible.

## The MaintNode Devices page

Open **MaintNode Devices** from the menu, under **Setup**. It lists every device
claimed by the current installation.

![The MaintNode Devices page](../_images/08-devices.png)

For each device you see:

- **Status** — **Online** if it has checked in within the last five minutes,
  otherwise **Offline**.
- **Device** — its name; click it to open the device page.
- **Last seen** — when it last checked in.
- **UUID** — the device's unique identity.
- **Health** — a warning chip if the device reports high **CPU**, memory (**MEM**),
  **DISK** usage, or **TEMP**erature.

A site with no devices yet shows *"No devices linked"* and an **Add device** button.

## Claiming a device

Every MaintNode carries a **label** with a QR code, its short ID, and the
credentials for its setup hotspot. **Claiming** registers the device to your
installation; Mechbase then sends it the credentials it needs to upload readings.

The quickest way is from the device itself: **scan the QR code** on its label with
your phone. It opens the device's **Device setup** page in Mechbase (sign in if
asked).

From a desk instead, open **MaintNode Devices**, click **Add device**, type the
device's UUID (it's on the label), and click **Go to device**.

![Adding a device by its UUID](../_images/08-add-device.png)

On the **Device setup** page — *"Choose where this device belongs"*:

1. Pick the **Installation** (if you belong to more than one).
2. Give it a **Device name** people will recognise — *"Compressor room node"*.
3. Click **Claim device**.

You're returned to the devices list with *"Compressor room node is now registered
to LPG Terminal"*. Once claimed, the same page shows the device's **Online** /
**Offline** status, lets you **Rename** it, and has **Send credentials again** — use
that if a newly claimed device doesn't come online.

If a device is already registered to another installation, Mechbase says so and
shows nothing more about it. A device it doesn't recognise at all reads *"This
device isn't registered with Arpedon yet"* — contact Arpedon.

> **Note:** Any member of the site can claim and connect devices, but in practice
> it's a commissioning job. Day-to-day users don't need this page — they just see
> the readings it produces.

## Getting it on the network

A MaintNode needs a network connection to upload. If it can't reach one on its own
(no DHCP on its Ethernet port, or Wi-Fi only), use its built-in **Network setup**
page:

1. On your phone or laptop, join the device's Wi-Fi hotspot —
   **MaintNode-xxxxxxxx**, with the password printed on the label.
2. Browse to **http://10.42.0.1**.
3. Set up **Ethernet** or join a **WiFi** network, review the **Change**, and
   **Apply** it. Changes that would cut you off can be staged for the next reboot
   instead; the **History** tab shows what was changed and when.

Once it's online and claimed, the device's status in Mechbase turns **Online**.

> **Screenshot needed (MaintNode):** the Network setup page at `10.42.0.1`.

## Connecting a channel to a point

With the device claimed and wired, connect each channel to the measurement point it
measures. Open the point, click **Edit** (`E`), scroll to **Sources**, and click
**Add source**.

![Adding a MaintNode source to a point](../_images/08-source-new.png)

1. **Source type** — choose **MaintNode** (MQTT is for your own devices; see the
   [MQTT cookbook](developers/mqtt.md)).
2. **Device** — one of the devices claimed by this installation.
3. **Group** — an existing acquisition group on that device, or **New group…**. A
   new group needs:
   - a **New group name**;
   - the **Hardware type** — **Built-in inputs**, **USB DAQ (USB-201)** (with its
     hardware ID and address), or **Modbus**;
   - the **Interval (s)** between measurement bursts (20 minutes by default), the
     **Sample rate (Hz)**, and the **Samples per burst**.
4. **Channel** — channel 0–15 on built-in inputs (0–7 is the first board, 8–15 the
   second).
5. **Sensor type**, and its settings:
   - **Accelerometer** — **Sensitivity (mV/g)** (100 by default) and **Offset**.
   - **0-10 V**, **4-20 mA**, **0-20 mA** — the **Min value** and **Max value** the
     signal range represents, and an optional **Aggregation** (mean, RMS, max, min)
     over the burst.
   - **Tachometer (RPM)** — a once-per-revolution pulse.
   - For Modbus: **Register value** or **Digital**.
6. Click **Add source**.

**Modbus groups** also need the connection — **TCP** (the **IP address** and **TCP
port** of the PLC or gateway, as the MaintNode sees it on the plant network) or
**Serial (RTU)** (port, baud rate, parity, stop and data bits) — and the **Unit ID**.
Each Modbus source then names its **Register address**, **Register type** (holding,
input, coil, or discrete input), **Data type** (16- or 32-bit integer, or float),
**Word order**, and an optional **Scale** and **Offset**. Digital channels can be
**normally open** or **normally closed**, and are recorded as on/off periods — ideal
for a run signal or a fault contact on a **State** point.

**Why a tachometer is worth wiring.** Put a tachometer in the same group as the
accelerometers on a machine and every vibration reading carries the shaft's
once-per-turn pulses. Mechbase then measures the actual shaft speed and the **1X**
and **2X** amplitude and phase of each reading
([Measurements, trends, and alarms](measurements.md#inspecting-a-vibration-reading)),
and the tachometer becomes the authority on whether the machine is running.

To change a source later, click its pencil on the point's edit page. A source keeps
its type, device, and group — to move it, remove it and add a new one. **Edit group
settings** changes the group's name and timing for every channel in it. **Remove
source** stops new readings arriving from it; readings already recorded stay on the
point.

## From device to trend

Once a device is claimed, online, and its channels connected, its data reaches
Mechbase like this:

1. On each group's schedule, the MaintNode measures its channels in a burst.
2. It stores the readings on the device, then **uploads** them to Mechbase —
   immediately when it's online, or as soon as it's back if not.
3. Each reading lands on the **measurement point** that channel is connected to.
4. From there it's an ordinary reading: it joins the **trend**, is scored against
   the point's **alarm rule**, and updates the asset's **state** ([Measurements, trends, and alarms](measurements.md)).

So the join between hardware and Mechbase is one line on a point: *this point is fed
by that device's channel*. After that, everything you learned about trends and
alarms applies automatically.

## Is my device healthy?

Because the readings only keep coming while the device is working, it's worth
knowing how to check one:

- On **MaintNode Devices**, a healthy device reads **Online**, with a recent **Last
  seen** and no **Health** warnings.
- Mechbase watches every connected point. If a point that's normally fed
  automatically misses three scheduled readings in a row, Mechbase flags it: the
  point page shows **No data** and since when, the asset's activity records *"No
  readings from … since …"*, and the asset shows up as **Silent** on Needs
  attention. When readings come back, the activity says *"Readings resumed"*.
- If a device goes **Offline**, check its power and network first. If it's online
  but a single point is silent, check the sensor and its wiring, and that the
  point's **Sources** still names the right channel.

> **Note:** For the wiring, mounting, and sensor specifics, follow the hardware's
> own user manual — it's the authority on sensor models, ranges, and installation.