Glossary#
Term |
What it means |
|---|---|
Installation |
A single physical site Mechbase monitors — a plant, terminal, factory, or vessel. Its number appears in the web address ( |
Section |
A major area of an installation (e.g. Utilities). |
Zone |
A specific location within a section (e.g. Pump Station). Locations read as |
Zone type |
A kind of zone (e.g. a room type), created by a room-list import. Documents added to a type appear on every zone of that type. |
Asset |
A piece of equipment (pump, compressor, panel…). Its equipment type is rotating, electrical, static, or infrastructure. |
ISO 10816 class |
The vibration severity class of a rotating machine (I–IV); it sets the default vibration alarm bands. |
Measurement point |
One specific thing measured on an asset, in one place — e.g. drive-end vibration. Named by its location (Motor DE). |
Measurement / reading |
A single value recorded at a point in time, automatically or by hand. Numbered per point (the number in its web address). |
Transducer type |
What a point measures: vibration, temperature, thermography, ultrasound, pressure, flow, current, voltage, tachometer, counter, boolean, state, production. |
Trend |
A point’s readings plotted over time, with alarm limits shown. Vibration points show a grid of trends, one per metric. |
Normal band |
Where a value usually sits — the middle 80% of its running readings over the previous 30 days. |
Waveform / spectrum |
The full vibration signal behind a reading, and its frequency content. Opened in the Inspect panel. |
1X / 2X |
The vibration at once and twice shaft speed, with its phase — measured when a tachometer is wired. |
Bearing |
A rolling-element bearing from the library (or added by you), with its defect frequencies BPFO, BPFI, BSF, FTF in orders of shaft speed. |
Baseline |
A point’s learned “normal”, used by relative alarm rules. Can be cleared or relearned from a date. |
Finding |
An analyst’s recorded diagnosis on a reading — fault, severity, recommended action, due date — with a work-order status (Open, Acknowledged, Closed). |
Alarm rule |
How a point’s status is judged — a method (threshold, narrowband envelope, maintenance-due), a direction, and Warning/Critical limits. An installation (or ISO) default, or a per-point override. |
Bearing band rule |
An alarm on a bearing’s defect band, as an absolute value or a multiple of the baseline. |
Health state |
An asset or point’s condition: Nominal, Check, Warning, or Critical. See Health states. |
Silent |
An asset whose sensors used to report but haven’t for 30 days, or whose live feed has stopped. |
Stale |
A running-state or device signal that hasn’t checked in recently. |
Production / running state |
Whether a machine is running (On / Off), from a tachometer, a run signal, or the vibration itself. Totalled as running hours. |
Run detection |
How a vibration sensor tells running from stopped, learned from its own history. |
State point |
An on/off signal (a fault contact, a run lamp) recorded as periods rather than a trend. |
Needs attention |
The list of every asset that isn’t Nominal, most urgent first, followed by silent assets — on the home page and its own page. |
Points page |
Every measurement point on the site in one filterable table. |
Hours page |
Running hours for every asset that tracks them. |
Dashboard |
A live board of chosen points, in sections, refreshing every minute. Built by staff; an automatic board shows live MaintNode points until one is built. |
Route |
A repeatable inspection round, made of stops and checks. |
Stop |
A zone or an asset visited during a route. |
Check |
One item completed on a route. Types: Pass / Fail, Numerical, Multi-check, Measurement. |
Survey |
A route built as you walk it, starting from an empty checklist. |
Run / execution |
One performance of a route — Running, Completed, or Cancelled. A route has at most one run in progress. |
Non-conformity (NC) |
A check that didn’t pass, graded Warning or Critical. Pinned to the asset’s activity until Resolved. |
Amend |
Filling in a completed run afterwards — skipped checks, late readings, photos, notes — by the person who ran it or a staff user. |
MaintNode |
The edge device wired to your sensors (built-in inputs, USB DAQ, Modbus) that measures on a schedule and uploads readings into Mechbase automatically. |
Acquisition group |
A set of channels on one MaintNode measured together, on the same hardware and schedule. |
Channel |
One input on a MaintNode device, connected to a measurement point as a source. |
Claiming |
Registering a MaintNode to your installation, from its label QR code or its UUID. |
Source |
Where a point’s data comes from automatically — a MaintNode channel, or an MQTT device channel. |
Undo |
The short-lived button that reverses a small delete (a reading, a note, an alarm override, a route check). |
Member |
A user on an installation’s Users list — they can open it and work with everything in it. |
Staff |
A user who can also build dashboards, amend others’ runs, delete equipment with history, and use the admin back office. |
Microsoft sign-in (SSO) |
Signing in with a Microsoft 365 work account, for organisations set up for it. |