Mechbase Manual

Glossary#

Term

What it means

Installation

A single physical site Mechbase monitors — a plant, terminal, factory, or vessel. Its number appears in the web address (/2012/).

Section

A major area of an installation (e.g. Utilities).

Zone

A specific location within a section (e.g. Pump Station). Locations read as Section / Zone. Zones have their own page for documents and photos.

Zone type

A kind of zone (e.g. a room type), created by a room-list import. Documents added to a type appear on every zone of that type.

Asset

A piece of equipment (pump, compressor, panel…). Its equipment type is rotating, electrical, static, or infrastructure.

ISO 10816 class

The vibration severity class of a rotating machine (I–IV); it sets the default vibration alarm bands.

Measurement point

One specific thing measured on an asset, in one place — e.g. drive-end vibration. Named by its location (Motor DE).

Measurement / reading

A single value recorded at a point in time, automatically or by hand. Numbered per point (the number in its web address).

Transducer type

What a point measures: vibration, temperature, thermography, ultrasound, pressure, flow, current, voltage, tachometer, counter, boolean, state, production.

Trend

A point’s readings plotted over time, with alarm limits shown. Vibration points show a grid of trends, one per metric.

Normal band

Where a value usually sits — the middle 80% of its running readings over the previous 30 days.

Waveform / spectrum

The full vibration signal behind a reading, and its frequency content. Opened in the Inspect panel.

1X / 2X

The vibration at once and twice shaft speed, with its phase — measured when a tachometer is wired.

Bearing

A rolling-element bearing from the library (or added by you), with its defect frequencies BPFO, BPFI, BSF, FTF in orders of shaft speed.

Baseline

A point’s learned “normal”, used by relative alarm rules. Can be cleared or relearned from a date.

Finding

An analyst’s recorded diagnosis on a reading — fault, severity, recommended action, due date — with a work-order status (Open, Acknowledged, Closed).

Alarm rule

How a point’s status is judged — a method (threshold, narrowband envelope, maintenance-due), a direction, and Warning/Critical limits. An installation (or ISO) default, or a per-point override.

Bearing band rule

An alarm on a bearing’s defect band, as an absolute value or a multiple of the baseline.

Health state

An asset or point’s condition: Nominal, Check, Warning, or Critical. See Health states.

Silent

An asset whose sensors used to report but haven’t for 30 days, or whose live feed has stopped.

Stale

A running-state or device signal that hasn’t checked in recently.

Production / running state

Whether a machine is running (On / Off), from a tachometer, a run signal, or the vibration itself. Totalled as running hours.

Run detection

How a vibration sensor tells running from stopped, learned from its own history.

State point

An on/off signal (a fault contact, a run lamp) recorded as periods rather than a trend.

Needs attention

The list of every asset that isn’t Nominal, most urgent first, followed by silent assets — on the home page and its own page.

Points page

Every measurement point on the site in one filterable table.

Hours page

Running hours for every asset that tracks them.

Dashboard

A live board of chosen points, in sections, refreshing every minute. Built by staff; an automatic board shows live MaintNode points until one is built.

Route

A repeatable inspection round, made of stops and checks.

Stop

A zone or an asset visited during a route.

Check

One item completed on a route. Types: Pass / Fail, Numerical, Multi-check, Measurement.

Survey

A route built as you walk it, starting from an empty checklist.

Run / execution

One performance of a route — Running, Completed, or Cancelled. A route has at most one run in progress.

Non-conformity (NC)

A check that didn’t pass, graded Warning or Critical. Pinned to the asset’s activity until Resolved.

Amend

Filling in a completed run afterwards — skipped checks, late readings, photos, notes — by the person who ran it or a staff user.

MaintNode

The edge device wired to your sensors (built-in inputs, USB DAQ, Modbus) that measures on a schedule and uploads readings into Mechbase automatically.

Acquisition group

A set of channels on one MaintNode measured together, on the same hardware and schedule.

Channel

One input on a MaintNode device, connected to a measurement point as a source.

Claiming

Registering a MaintNode to your installation, from its label QR code or its UUID.

Source

Where a point’s data comes from automatically — a MaintNode channel, or an MQTT device channel.

Undo

The short-lived button that reverses a small delete (a reading, a note, an alarm override, a route check).

Member

A user on an installation’s Users list — they can open it and work with everything in it.

Staff

A user who can also build dashboards, amend others’ runs, delete equipment with history, and use the admin back office.

Microsoft sign-in (SSO)

Signing in with a Microsoft 365 work account, for organisations set up for it.